Product Details

R900503335 DA20-1-5X/200-17 Rexroth Pressure cut-off valve, pilot-operated

Place of Origin Germany
Brand Name Rexroth
Certification CE ISO
Model Number R900503335 DA20-1-5X/200-17
Min.Order Quantity 1 pc
Price contact us
Packaging Details standrd package
Delivery Time 5-7 workdays
Payment Terms T/T,Western Union
Supply Ability 60 pcs

Product Features

Technical data

Size

10 25 32

Weight

Type DA

kg

3.8 7.7 13.5

Type DA …FS

kg

4.4 8.3 14.1

Type DAC …

kg

1.2

Type DAC 30…

kg

1.4

Type DAC 30…FS

kg

1.9

Installation position

any

Ambient temperature range

NBR seals

°C

-30 … +80

FKM seals

°C

-20 … +80

hydraulic

Size

10 25 32

Maximum operating pressure

Port P

bar

315

Port A 1)

bar

315

Port T 2) 3)

bar

100

Port Y 2) 3)

bar

100

Set pressure range

Pressure rating 50

bar

25 … 50

Pressure rating 100 4)

bar

50 … 100

Pressure rating 200 4)

bar

100 … 200

Pressure rating 315 4) 5)

bar

200 … 315

Switching pressure differential

Version "FS"

freely adjustable (10 % to 50 % of nominal set pressure)

Version "10" 4)

%

10

Version "17" 4)

%

17

Maximum flow

Version "FS"

l/min

120 250 400

Version "10"

l/min

40 80 120

Version "17"

l/min

60 120 240

Hydraulic fluid

Mineral oil (HL, HLP) according to DIN 51524, other hydraulic fluids on request

Hydraulic fluid temperature range

NBR seals

°C

-30 … +80

FKM seals

°C

-20 … +80

Viscosity range

maximum

mm²/s

10 … 800

Recommended

mm²/s

20 … 60

Maximum admissible degree of contamination of the hydraulic fluid 6)

Class 20/18/15 according to ISO 4406 (c)
1) (after switching P to T)
2) Attention! The applied pressure adds to the set pressure! The switching pressure differential remains unchanged within the setting range!
3) The tank pressure must not exceed the pump pressure.
4) For switching pressure differential adjustment, the following points must be observed:The top and bottom switching points must be within the setting range of the pressure rating (e.g. for a pressure rating of 100 bar: top switching point 100 bar, bottom switching point 50 bar ≙ 50 % switching pressure differential)– The minimum switching pressure differential mainly depends on the system (set pressure, pump and actuator flow, accumulator size and preload, line length and resistance, etc.) Here, the valve offers the possibility of optional adjustment of the switching pressure differential to the system. For these reasons, however, the minimum adjustable switching pressure differential of the valve cannot always be realized at the system. – Generally: Reduce the tubing between pressure cut-off valve and hydraulic accumulator to a minimum and ensure depressurized pilot oil (Y) discharge as possible. – For the switching pressure differential factory setting, refer to the respective information sheet.
5) Type DA …FS... 150 to 315 bar
6) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

For applications outside these parameters, please consult us!

Skype Contact Now